POINT 430 VINYL FIX Vinylester Base Chemical Anchor

A two-component styrene-free vinylester chemical anchor for structural or heavy loads, CE marked and ETA assessed. For use in a variety of materials such as concrete, cracked concrete, reinforced concrete, solid and hollow bricks masonry and wood.

SKU: 03-2-0-430
Colour: Grey
Volume: 300 ml
  • Chemical resistance
  • Fire resistance
  • Seismic certification
  • Wet concrete and flooded hole

POINT 430 VINYL FIX is a bi-component vinyl ester styrene free chemical anchor for structural/ high loads, CE marked and ETA assessed for use in concrete.
It is certified for threaded rods to be used in non-cracked concrete from diameters M8 to M30, in cracked concrete from diameters M10 to M20, in solid masonry from diameters M8 to M16, in hollow masonry from diameters M8 to M12 and in timber from diameters M8 to M16.
It is certified for rebars to be used in non cracked concrete from diameters Ø8 mm to Ø32 mm and for post-installed rebar connections in reinforced concrete for diameters from Ø8 mm to Ø32 mm.
This resin has seismic qualification, fire resistance and chemical resistance. It can be used when base material temperature is between -10°C and +40°C. Suitable for use in wet concrete and flooded holes.
Due to its strong adhesion and ease of penetration into holes and hollow materials, the resin allows a secure attachment without expansion and without stresses in the base material, which allows you to make fixings close to the corners and edges of base material.

 

ETA (European Technical Assessments) updated according to the Construction Product Regulation 305/2011.
ETA-09/0140: Assessment according to EAD-330499 for uncracked concrete, Option 7, for diameters from M8 to M30 and for rebars from Ø8 mm to Ø32 mm. Performace for cracked concrete, Option 1, with rod M10-M12- M16-M20. Seismic qualification according to EOTA Technical Report TR049. The product is qualified in seismic category C1 for diameters M12-M16-M20 and seismic category C2 for diameters M12-M16. The product is homologated for fixings with a variable anchorage depth, to give the designer a high degree of flexibility. Maximum
anchoring depth up to twenty times the nominal diameter of the threaded rod. Certified service temperatures are in the ranges: -40°C/+40°C (T° max long period = +24°C) ,-40°C/+80°C (T° max long period = +50°C) and -40°C/+120°C (T° max long period = +72°C). ETA-09/0246: Assessment according to EAD-330087 for post-installed rebar connections in reinforced concrete for diameters from Ø8 mm to Ø32 mm. Minimum anchorage depth according to Eurocode 2 in case of uncracked and cracked concrete. Fire resistance, up to a maximum of R240. Assessment for seismic condition according to the EAD 331522 for diameters from Ø12 mm to Ø32 mm. Certified service temperatures are in the range: -40°C/+80°C (T° max long period = +50°C). Concrete category Cl 0,4 max. Possibility of installing the anchor using hollow drill bits. This installation mode avoids the dust removal procedure by means of a blower pump and a metal brush, and thus significantly reduces the installation time. Possibility to use the product in dry, wet concrete and with flooded hole (flooded hole only with threaded bars). The product hardening reaction also takes place in the presence of water. Base material temperature (concrete, bricks, etc…) for installation should be between -10 °C and +40 °C. Suitable also for base material like solid and hollow masonry, wood. VOC according to the French Decree 2011-321 and according to the standard ISO 16000/EN 16516.

 

 

Cleaning:
Drill the hole and check it’s perpendicularity. Blow the hole with an appropriate pump blower (or compression air), clean the lateral surface of the hole with an appropriate steel brush, blow again in the hole until there is no dust and/or any residual material inside. We strongly recommend use of the steel brush to clean hole sides.
Opening:
Unscrew the front cup, pull-out the steel closing clip according to the following operations: 1) Insert the mixer in the eye of the plastic extractor. 2) Pull the extractor to unhook the steel closing clip of the foil. After that, screw on the mixer and insert the cartridge in the gun. Use protections for hands and face.
Cartridge preparation:
Use the correct dispenser.
Before starting to use the cartridge, eject a first part of the product, being sure that: 1) Trough the mixer (transparent) see that the flux of product is compound of the part A (white color) end of part B (black color). 2) The two components are completely mixed. The complete mixing is reached only after that the product, obtained by mixing the two component, comes out from the mixer with an uniform color. Now the cartridge is ready to be used.
Injection:
1) Inject resin into the hole up to fill it 2/3rds. In hollow bricks use the plastic sleeve and inject the resin inside.
2) Before insert the rod, verify that the element is dry and free oil and other contaminants. Insert threaded stud turning back and forth to avoid presence of air in the fitted hole.
3) For the installation and the following anchor load phase, respect the open time and curing time detailed in the technical data sheet and in the label of the product.
4) Before to load the anchor, check the hardened of the product.
5) The cartridge can be used again screwing the cup and replacing the mixer. Remember to eject a first part of the product, see point 3.

Store in a vertical position in a dry place at a temperature between +5 °C and +30 °C. Expiry date – 15 months from the date of manufacture, in compliance with the storage rules. Quantity in a box– 15 pcs. Quantity in the palette – 960 pcs. Unit weight – 0.570 kg. Transport temperature from +5 °C to +30 °C.